| Peer-Reviewed

Comparison Between Heat Pipes Based Condenser and Conventional Condenser of Power Plant

Received: 29 March 2022    Accepted: 4 May 2022    Published: 24 October 2022
Views:       Downloads:
Abstract

Condenser is a vital part in the steam circuit of power plant. But since inception there wre no modifications in the design of this vital component. The only variations are, the type of nonferrous tubes and tube matrix according load on the condenser. In this paper design modification of condenser suggested viz. type heat transfer utilized in the condenser. Two phase heat transfer suggested instead single heat phase heat transfer as in conventional condenser. This type of two phase heat transfer achieved by using heat pipes. The heat pipe designed for this special application of steam condensation. A laboratory model of condenser with 16 heat pipes fabricated and experiments were conducted on this heat pipe based condenser. The comparison of the performances of conventional condenser made of simple copper tubes and heat pipe based condenser were presented in this paper. Effectiveness calculations, heat transfer surface area comparison, comparison of exergy analysis for the both type of condenser presented in this paper. The comparative study reveals that the heat pipe based condenser had much improved performance parameters over the condenser made up with copper tubes.

Published in World Journal of Applied Physics (Volume 7, Issue 3)
DOI 10.11648/j.wjap.20220703.11
Page(s) 32-42
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2024. Published by Science Publishing Group

Keywords

Wickless Heat Pipe, Thermosyphon, Steam Condenser, Exergy, Heat Transfer Coefficient

References
[1] S. Seshan and D. Vijayalakshmi,” Heat Pipes- concepts, Materials, and Applications” Energy MANAGEMENT, Vol 26, 1986.
[2] Heat Pipes, Second Edition, P. Dunn and D. A. Reay, Pergamon Press.
[3] Amir Faghri “Heat Pipe Science and Technology” Taylor and Francis, Washngton Dc, USA, 1995.
[4] Heat Pipe Waste Heat Recovery by D. A. Littwin, J. M. C. Curley Journal of Heat Recovery System, Elseveir Vol 1, Issue 4, 1981, Page: 339-348.
[5] Vasiliev L. L., Grakovich P., Khrustalev D. K., Kiselev V. G., Matveev Yu. (1984) Heat pipes and heat pipe exchangers for heat recovery systems, Journal of Heat Recovery Systems, Vol. 4, Iss. 4, pp. 227-233.
[6] Hong Z, Jun Zhuang: Research, Development and Industrial Application of Heat Pipe Technology in China, Applied Thermal Engineering, 2003, 23, 9, 1067-1083.
[7] L Vasiliev, Review “Heat Pipes in modern Heat Exchangers, Applied Thermal Engineering 25 (2005) 1-19.
[8] Steam condensation by Heat Pipes, Journal of Physics, conference series, 1473 (2020) 012028 doi. 10.1088/1742-6596/1473/1/012028.
[9] T. Mallikharjuna Rao and S. S. Rao: Retrofitting of power plant condensers with heat pipe heat exchanger: A case study by VIII Minsk International Seminar “Heat Pipes, Heat Pumps, Refrigerators, Power Sources”, Minsk, Belarus, September 12–15, 2011.
[10] Compact Heat Exchangers by Kays and London, Mc Graw Hill Book Company.
[11] Azad, E, “A design procedure for gravity assisted heat pipe heat exchanger, Journal of heat recovery system, 1984.
[12] Antun Galovic, Marija Zivic and Mato Kokanovic: Analysis of Exergy Destruction of an Evaporator or/and a Condenser Published in Strojarstvo 51 (1) 73-78 2000, ISSN 056201887.
Cite This Article
  • APA Style

    Mallikharjuna Rao Tarla. (2022). Comparison Between Heat Pipes Based Condenser and Conventional Condenser of Power Plant. World Journal of Applied Physics, 7(3), 32-42. https://doi.org/10.11648/j.wjap.20220703.11

    Copy | Download

    ACS Style

    Mallikharjuna Rao Tarla. Comparison Between Heat Pipes Based Condenser and Conventional Condenser of Power Plant. World J. Appl. Phys. 2022, 7(3), 32-42. doi: 10.11648/j.wjap.20220703.11

    Copy | Download

    AMA Style

    Mallikharjuna Rao Tarla. Comparison Between Heat Pipes Based Condenser and Conventional Condenser of Power Plant. World J Appl Phys. 2022;7(3):32-42. doi: 10.11648/j.wjap.20220703.11

    Copy | Download

  • @article{10.11648/j.wjap.20220703.11,
      author = {Mallikharjuna Rao Tarla},
      title = {Comparison Between Heat Pipes Based Condenser and Conventional Condenser of Power Plant},
      journal = {World Journal of Applied Physics},
      volume = {7},
      number = {3},
      pages = {32-42},
      doi = {10.11648/j.wjap.20220703.11},
      url = {https://doi.org/10.11648/j.wjap.20220703.11},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.wjap.20220703.11},
      abstract = {Condenser is a vital part in the steam circuit of power plant. But since inception there wre no modifications in the design of this vital component. The only variations are, the type of nonferrous tubes and tube matrix according load on the condenser. In this paper design modification of condenser suggested viz. type heat transfer utilized in the condenser. Two phase heat transfer suggested instead single heat phase heat transfer as in conventional condenser. This type of two phase heat transfer achieved by using heat pipes. The heat pipe designed for this special application of steam condensation. A laboratory model of condenser with 16 heat pipes fabricated and experiments were conducted on this heat pipe based condenser. The comparison of the performances of conventional condenser made of simple copper tubes and heat pipe based condenser were presented in this paper. Effectiveness calculations, heat transfer surface area comparison, comparison of exergy analysis for the both type of condenser presented in this paper. The comparative study reveals that the heat pipe based condenser had much improved performance parameters over the condenser made up with copper tubes.},
     year = {2022}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Comparison Between Heat Pipes Based Condenser and Conventional Condenser of Power Plant
    AU  - Mallikharjuna Rao Tarla
    Y1  - 2022/10/24
    PY  - 2022
    N1  - https://doi.org/10.11648/j.wjap.20220703.11
    DO  - 10.11648/j.wjap.20220703.11
    T2  - World Journal of Applied Physics
    JF  - World Journal of Applied Physics
    JO  - World Journal of Applied Physics
    SP  - 32
    EP  - 42
    PB  - Science Publishing Group
    SN  - 2637-6008
    UR  - https://doi.org/10.11648/j.wjap.20220703.11
    AB  - Condenser is a vital part in the steam circuit of power plant. But since inception there wre no modifications in the design of this vital component. The only variations are, the type of nonferrous tubes and tube matrix according load on the condenser. In this paper design modification of condenser suggested viz. type heat transfer utilized in the condenser. Two phase heat transfer suggested instead single heat phase heat transfer as in conventional condenser. This type of two phase heat transfer achieved by using heat pipes. The heat pipe designed for this special application of steam condensation. A laboratory model of condenser with 16 heat pipes fabricated and experiments were conducted on this heat pipe based condenser. The comparison of the performances of conventional condenser made of simple copper tubes and heat pipe based condenser were presented in this paper. Effectiveness calculations, heat transfer surface area comparison, comparison of exergy analysis for the both type of condenser presented in this paper. The comparative study reveals that the heat pipe based condenser had much improved performance parameters over the condenser made up with copper tubes.
    VL  - 7
    IS  - 3
    ER  - 

    Copy | Download

Author Information
  • Material Technology Division, Central Power Research Institute, Bangalore, India

  • Sections